When the trades don't talk to each other, @#$% happens!

     I know I have blogged about this in the past, but this is the first time I have seen this particular defect in "New Construction."  It usually occurs in homes that have been re-roofed.  I am talking about compromised attic venting due to "opposing" systems being installed. 

     Older homes typically had gable vents if that was the type of roof that was installed.  As we came to understand how venting works, and came to understand the problems associated with inadequately vented attics and roof structures, we moved away from the use of gable vents.  Gable venting relies on movement through the vents from one end to the other to change the air in the attic and hopefully to carry any moisture that has entered the attic with it.  While in some cases this can be adequate it often left areas of the attic "under-ventilated" due to poor circulation.  The system was also subject to poor venting depending on the house orientation and prevailing wind direction.

     The next approach was to have soffit vents that circulated air up to roof vents located near the ridge of the roof.  This was better but could still be affected by wind direction and in some cases the vents could be buried in snow drifting across the ridge.

     By far the best method is to have the soffit vents in conjunction with continuous type ridge vents.  As wind moves across the ridge from any direction it acts to pull air out of the attic and would create a negative pressure on the attic if it were not for the soffit vents that allow for air to enter the attic----thus creating good air circulation.  I discussed these principles in my blogs, "What is Giovanni Venturi doing in my attic" and in , "Not all short-circuits are electrical."

     So how does this happen in New Construction?

     It is easier to see how it happens in old.  For example:  the gable vents are already there----and no one thinks to cover them up.  The roof vents are already there----and it is easier to put another roof vent over the hole than it is to patch the hole and roof over it.  In new construction we are sort of back to, "What were they thinking?"  Maybe the framers were just used to cutting the holes but the roofers where trying to do better?  Maybe the plans called for both?  Lack of communication?  Whatever reason it shows a serious flaw in someone's understanding of basic building science.  The following picture, from inside the attic, shows how the air is likely to flow to the continuous-type roof vent----pulling little air from the soffit vents.

poor roof venting

Charles Buell

     PS, for those of you that are new to my blog (or for some other "unexplained" reason have never noticed)sunsmileall  pictures and smiley-face inserts (emoticons) (when I use them) have messages that show up when you point at them with your cursor.

sign me up

 

 

 

 

picture logo

                                                               * * * * * * * * * * * * * * * * * * * * * * * * *

Click on the Rose A Group by any other name. to check out: AHA!---A Forum of Landmark Proportions---your Group

PS, for those of you that are new to my blog (or for some other "unexplained" reason have never noticed)sunsmileall pictures and smiley-face inserts (emoticons) (when I use them) have messages that show up when you point at them with your cursor.

My WORDLESS WEDNESDAY pictures and some selected POEMS & STORIES.

Just quack on me to subscribe

 

The Human Rights Campaign   QR code for Charles Buell Inspections Inc  ASHI.org

4 commentsCharles Buell, Seattle Home Inspector • August 22 2008 04:46PM

Comments

That be what happens when there is a lack of communication. Ohwell, I guess they could just Duct tape the one vent closed.

Sean Allen

Posted by International Financing Solutions almost 4 years ago

Thank goodness for Duct tape ...... A definite problem solver for many builders and handymen.

Sean Allen

Posted by International Financing Solutions almost 4 years ago

Charlie,

Great detail, great understanding, great blog. You are the master.

Posted by Steven L. Smith, Bellingham, Wa. Home Inspector (King of the House Home Inspection, Inc) almost 4 years ago

Sean, Duct tape----part of the solution or part of the problem:)

Grasshopper, thanks

Posted by Charles Buell, Seattle Home Inspector (Charles Buell Inspections.com) almost 4 years ago

Participate



(optional)
What does the graphic say?